M5、2-position 5-way valve、Single electronic control、Mechanical spring return、Valve width 10mm、FAS-L10-M52-MT-M5-M8、8100402058

M5、2-position 5-way valve、Single electronic control、Mechanical spring return、Valve width 10mm、FAS-L10-M52-MT-M5-M8、8100402058

Ordering code: 8100402058
Part number : FAS-L10-M52-MT-M5-M8
  • Function: 2x3/2C, 2x3/2U, 2x3/2H; 5/2-way valve, single solenoid control; 5/2-way valve, double solenoid control; 5/3C, 5/3U, 5/3E
  • Valve width: 10 mm
  • Flow rate: 125…220 l/min
  • Operating voltage: 5, 12 and 24 V DC
Collect 询盘

Related recommendations

  • Function Parameter
  • Resource Download
  • Related accessories
TypeIn-line valve M5,with M8 connector
2-position 8-way valve, single solenoid controlInternal pilot air supply
IllustrateReset method: mechanical spring reset


Main technical parameters

Valve functionT32-AT32-MM52-AB52M52-MP53
Normal positionC1)U2)H4)C1)U2)H4)---C1)U2)E3)
Stable positionSingle electronic controlDual electronic controlSingle electronic controlSingle electronic control
Reset method: air resetYesNoYes-NoNo
Reset method: mechanical spring resetNoYesNo-YesYes
Air port vacuum operationNoWhen only external pilot is used
DesignPiston slide valve
Sealing principleSoft seal
Drive modeElectric
Control methodPilot control
Pilot air sourceInternal or external
Exhaust functionWith flow control
Rated flow [l/min]150135125125220
190210
Flow rate on manifold board [l/min]150135125125220
190210
Switching time on/off [m s]6/168/11


-8/2410/30
Conversion time [m s]7-16
Valve width [mm]10
Air port    1, 2, 3, 4,5M5
Air port    12/14M3
Product weight  [g]5554
45554455
Certificationc UL us - Certification (OL)
CE marking (see Declaration of Conformity)Comply with EU EMC directive
Corrosion resistance grade CRC2

1) C= Normally closed/mid-closed type

2) U=Normally open/medium voltage type

3) E=Mid-discharge type

4) H=2x 3/2-way valve integrated in one housing, 1 x normally closed and 1 x normally open

Electrical parameters
Electrical connectionM8 connector
Working voltage [V DC]5, 12 2 and 4±10%
Power [W]1,By reducing the holding current function to 0.35
Continuous power rate ED [%]100
Protection class according to EN 60529IP40 (with socket), IP65 (for M8)
Material
CaseRefined aluminum alloy
SealsHNBR, NBR
Material considerationsRoHS compliant
Working and environmental conditions
Valve functionT32-A1)T32-M2)M52-AB52M52-MP53
Working mediumCompressed air according to ISO 8573-2010 [7:4:4]
Work pressure    Internal [bar]1.5 … 82.5 … 82.5 … 81.5 … 83 … 83 … 8
Work pressure    External [bar]1.5 … 10–0.9 … 10–0.9 …8–0.9 … 10
Pilot pressure 3) [bar]1.5 … 82 … 82.5 … 81.5 … 83 … 8
Ambient temperature  [°C]–5 … +50, –5 … +60, with holding current reduction function
Medium temperature  [°C]–5 … +50, –5 … +60, with holding current reduction function

1) Air reset